{"best_oa_location":{"endpoint_id":null,"evidence":"deprecated","host_type":"publisher","is_best":true,"license":"cc-by","oa_date":"2025-09-08","pmh_id":null,"repository_institution":null,"updated":"deprecated","url":"https://link.springer.com/content/pdf/10.1007/s43452-025-01321-4.pdf","url_for_landing_page":"https://doi.org/10.1007/s43452-025-01321-4","url_for_pdf":"https://link.springer.com/content/pdf/10.1007/s43452-025-01321-4.pdf","version":"publishedVersion"},"data_standard":2,"doi":"10.1007/s43452-025-01321-4","doi_url":"https://doi.org/10.1007/s43452-025-01321-4","first_oa_location":{"endpoint_id":null,"evidence":"deprecated","host_type":"publisher","is_best":true,"license":"cc-by","oa_date":"2025-09-08","pmh_id":null,"repository_institution":null,"updated":"deprecated","url":"https://link.springer.com/content/pdf/10.1007/s43452-025-01321-4.pdf","url_for_landing_page":"https://doi.org/10.1007/s43452-025-01321-4","url_for_pdf":"https://link.springer.com/content/pdf/10.1007/s43452-025-01321-4.pdf","version":"publishedVersion"},"genre":"journal-article","has_repository_copy":false,"is_oa":true,"is_paratext":false,"journal_is_in_doaj":false,"journal_is_oa":false,"journal_issn_l":"1644-9665","journal_issns":"1644-9665,2083-3318","journal_name":"Archives of Civil and Mechanical Engineering","oa_locations":[{"endpoint_id":null,"evidence":"deprecated","host_type":"publisher","is_best":true,"license":"cc-by","oa_date":"2025-09-08","pmh_id":null,"repository_institution":null,"updated":"deprecated","url":"https://link.springer.com/content/pdf/10.1007/s43452-025-01321-4.pdf","url_for_landing_page":"https://doi.org/10.1007/s43452-025-01321-4","url_for_pdf":"https://link.springer.com/content/pdf/10.1007/s43452-025-01321-4.pdf","version":"publishedVersion"}],"oa_locations_embargoed":[],"oa_status":"hybrid","published_date":"2025-09-08","publisher":"Springer Science and Business Media LLC","title":"Elevated temperature response and fire resistance considerations of 3D-printed concrete: small- to medium-scale wall experiments","updated":"2025-09-14T03:39:29Z","year":2025,"z_authors":[{"author_position":"first","is_corresponding":true,"raw_affiliation_strings":["Faculty of Civil and Environmental Engineering, West Pomeranian University of Technology in Szczecin, 70-311, Szczecin, Poland"],"raw_author_name":"Pawel Sikora"},{"author_position":"first","is_corresponding":true,"raw_affiliation_strings":null,"raw_author_name":"Pawel Sikora"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":["Faculty of Civil and Environmental Engineering, West Pomeranian University of Technology in Szczecin, 70-311, Szczecin, Poland"],"raw_author_name":"Szymon Skibicki"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":null,"raw_author_name":"Szymon Skibicki"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":["Fire Research Department, Building Research Institute (ITB), 00-611, Warsaw, Poland"],"raw_author_name":"Jakub Bielawski"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":null,"raw_author_name":"Jakub Bielawski"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":["Faculty of Civil and Environmental Engineering, West Pomeranian University of Technology in Szczecin, 70-311, Szczecin, Poland"],"raw_author_name":"Mateusz Techman"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":null,"raw_author_name":"Mateusz Techman"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":null,"raw_author_name":"Karol Federowicz"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":["Faculty of Civil and Environmental Engineering, West Pomeranian University of Technology in Szczecin, 70-311, Szczecin, Poland"],"raw_author_name":"Karol Federowicz"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":["Fire Research Department, Building Research Institute (ITB), 00-611, Warsaw, Poland"],"raw_author_name":"Wojciech W\u0119grzy\u0144ski"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":null,"raw_author_name":"Wojciech W\u0119grzy\u0144ski"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":["Faculty of Civil and Environmental Engineering, West Pomeranian University of Technology in Szczecin, 70-311, Szczecin, Poland"],"raw_author_name":"Pawel Sikora"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":null,"raw_author_name":"Pawel Sikora"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":["Faculty of Civil and Environmental Engineering, West Pomeranian University of Technology in Szczecin, 70-311, Szczecin, Poland"],"raw_author_name":"Szymon Skibicki"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":null,"raw_author_name":"Szymon Skibicki"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":null,"raw_author_name":"Jakub Bielawski"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":["Fire Research Department, Building Research Institute (ITB), 00-611, Warsaw, Poland"],"raw_author_name":"Jakub Bielawski"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":["Faculty of Civil and Environmental Engineering, West Pomeranian University of Technology in Szczecin, 70-311, Szczecin, Poland"],"raw_author_name":"Mateusz Techman"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":null,"raw_author_name":"Mateusz Techman"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":null,"raw_author_name":"Karol Federowicz"},{"author_position":"additional","is_corresponding":false,"raw_affiliation_strings":["Faculty of Civil and Environmental Engineering, West Pomeranian University of Technology in Szczecin, 70-311, Szczecin, Poland"],"raw_author_name":"Karol Federowicz"},{"author_position":"last","is_corresponding":false,"raw_affiliation_strings":["Fire Research Department, Building Research Institute (ITB), 00-611, Warsaw, Poland"],"raw_author_name":"Wojciech W\u0119grzy\u0144ski"},{"author_position":"last","is_corresponding":false,"raw_affiliation_strings":null,"raw_author_name":"Wojciech W\u0119grzy\u0144ski"}]}
